The equipment involved includes seat belt impact tester, seat belt overall static tester, seat belt overall slide tester, seat belt overall dynamic load overall static load tester, simulator, seat belt tension tester, salt spray test chamber And other equipment. The following is the details of the device:
ZD-711 belt impact tester (overall dynamic load)
First, the main purpose of the belt according to the latest standard GB6096-2009 "safety belt detection method" developed for the overall dynamic load carrying capacity of the belt detection equipment.
Second, the main technical indicators of high-speed single-chip data acquisition and processing system, continuous sampling time 20s, continuous sampling frequency 30KHZ, automatically lock the maximum impact value;
Dynamic force sensor: measuring range (0~20)KN; measuring accuracy: ±2.0% of full scale range;
Meet the standards: GB6095-2009 "seat belt", GB6096-2009 "safety belt detection method"
ZD-712 seat belt overall static load tester First, the main purpose Seat belt overall static load tester, is based on the new seat belt GB6096-2009 "safety belt detection method" design, used as the seat belt's overall static load capacity test.
Second, the main technical indicators force measurement system: digital display real-time tensile force value;
Mobile time timer device: set the time to automatically alarm reminder, the time device can be installed according to user needs to the appropriate location;
Meet the standard: GB/T6096-2009 "safety belt test method"
ZD-719 seat belt test rubber dummy one, main use:
Tests for various performances of seatbelts are in full compliance with the dynamic load and overall static load tests within the new national standards.
Second, the main technical indicators:
40mm thick rubber on the outer surface; Shore hardness: greater than 90;
Simulated quality: 100kg ± 2kg;
Meet the standard: Appendix A of GB/T6096-2009 "Safety belt test method"
ZD-715 seat belt overall dynamic load, static load tester I. The main purpose is based on the new seat belt GB6096-2009 "belt belt detection method" design, mainly used for dynamic load carrying performance (impact performance) and seat belts as a whole Static load tester dedicated experimental instruments.
Second, the main technical indicators seat belt dynamic load:
High-speed single-chip data acquisition and processing system, continuous sampling time 20s, continuous sampling frequency 30KHZ, automatically lock the maximum impact force value; dynamic force sensor: measurement range (0 ~ 20) KN;
Seat belt static load:
Force measurement system: digital display real-time tensile force value;
Mobile time timer device: set the time to automatically alarm reminder, the time device can be installed according to user needs to the appropriate location;
Meet the standards: GB6095-2009 "seat belt", GB6096-2009 "safety belt detection method"
ZD-717 seat belt overall sliding tester I. Instrument introduction The seat belt overall sliding tester is designed according to the new national standard of the seat belt and is used to test the ability of the surrounding belt to withstand the overall sliding down. GB/T6096-2009 "safety belt test method" in the 4.5 test requirements.
Second, the main technical indicators with a hanging point with a fixed hanging point distance of 200 ~ 300mm;
The dummy is equipped with anti-friction protection pads, which can effectively protect the dummy and extend the life of the dummy.
Meet the standard: GB/T6096-2009 "safety belt test method"
ZD-718 belt tension testing machine I. The main purpose is mainly used for the main belt safety belt, safety rope static load test; static load test parts; buffer deformation test, accidental opening force test.
Second, the instrument features 1, the use of high-precision, all-digital speed control system and precision reducer, drive precision without backlash screw test, to achieve a wide range of test speed adjustment, test process, low noise, smooth operation.
2. The universal joint adopts a cross pin structure and has a swing angle limiting function. On the one hand, it facilitates clamping of the sample to ensure concentricity of the test. On the other hand, it eliminates the influence of irregular samples on the sensor.
3, touch key operation mode, LCD display real-time display. The display interface can display the test method selection interface, test parameter selection interface, test operation and result display interface and curve display interface, which is convenient and quick.
4. It has two protection modes: mechanical protection and software. It will stop automatically when it exceeds the limit height, and automatically stop when it exceeds the rated load; and it also has an over-current emergency stop switch.
Third, the main technical indicators 1, models: two arms (LCD display)
2, the maximum test force: 50kN
3, accuracy level: 1 level 4, test force accuracy: better than the indicated ± 1%
5, test force: minimum resolution 0.01N
6, displacement measurement: resolution is 0.01mm
7, deformation accuracy: better than ± 1%
8, speed range: 1mm/min~~200mm/min
9, test stroke: 600mm (can be customized according to customer needs)
10, stretching space: 600mm (can be customized according to customer needs)
11, compression space: 600mm (can be customized according to customer needs)
12. Test protection function: overload protection 13, safety protection device: limit switch 14, power supply: 220V50Hz
Fourth, the applicable standard GB6095-2009 "belt" GB6096-2009 "safety belt inspection method"
Microscope Slides And Cover Slips
1. The glass slide is used to put the sample to be tested, and the cover glass is covered on the sample to be tested.
2. The glass slide is at the bottom, which is the carrier for the material you want to observe, that is, you want to put something on it.
3. The cover glass is smaller than the slide glass. The glass slide is mainly used to hold the observation objects. The cover glass is covered on the slide glass and used for fixing.
4. The glass slide is a thicker piece of glass in the transfer slide, which is used to carry the real object. The cover fragment is the small round or square thin one.
5. Mounting is a general term for a set of things, including slides, coverslips and loaded objects
6. The cover glass is square, the slide glass is rectangular, and the width is longer than the side of the cover glass.
microscope slide and cover slip,microscope slide and cover slip cube,microscope slide dimensions and cover slip
Yong Yue Medical Technology(Kunshan) Co.,Ltd , https://www.yonyue.com