Hobbing machine mechanical refinement technology (2)


3.d round eccentricity correction. At this time, the correction target is the cycle error of the worm pair, and the principle and method are the same as the above 2. This method will make the d wheel (or e wheel) fixed, thus reducing the choice of the matching gear wheel, that is, limiting the range of machining teeth.

4. Use the differential chain to correct. This method is similar to the principle of the above-mentioned measurement and control scheme, that is, using the machine differential system to provide an additional opposite motion to cancel according to the error. But just add a cam here. As shown in Figure 1. The gears a', b', c', d'4 are differential hanging wheels, where a' is replaced by a cam, b' is regarded as a swinging lever, and c' and d' are amplification ratio adjusting gears. a′′~b′′ is the feed suspension wheel set, and a~e are the split tooth suspension wheel sets. Adjust the feed hanging wheel so that the axis of the differential hanging wheel a' rotates synchronously with the machine table, install the cam on the a' shaft, install a swing rod on the b' shaft, and use the spring to ensure that the swing rod and the cam are unidirectional. Closely, the increase in cam will increase the b' axis by a rotary motion that brings an additional motion to the table through c', d', differential mechanisms e, f, a, b, c, d and the worm To offset the previously measured transmission error.

The machining of the cam is based on the test error curve, and the shape of the cam envelope is the shape of the test curve. Early limited to processing means, only cam processing according to the long-period error test curve, and need to leave a certain margin first, then mount the cam and then test, according to the test results, then use the boring tool to correct the cam (the cam material is made of plexiglass) To facilitate processing), so repeated several times. This method is mainly to correct the long cycle error of the machine tool. With the development of computer technology and CNC machining technology, corrections have been made based on transmission error (including long-period error and short-term cycle error) curves. The test curve obtained by the FMT test system [1][2] is composed of 1024 test points per week. After converting these points into the CNC milling machine, the cam with a fairly accurate shape can be processed. Therefore, the long cycle error of the machine tool and most of the short cycle error (a small number of high frequency errors are not reflected due to interference between the wheel and the cam on the pendulum) can be compensated and corrected, and the accuracy is more remarkable.

Third, the conclusion

The premise of realizing mechanical refinement is precision measurement, and after measurement, according to the measurement and analysis results, some large error links in the transmission chain, such as the shaft bent, the hole is biased, the teeth are missing, the sleeve is loose... ...and the first replacement, this work is very easy to do with the FMT test system. On this basis, the inaccurate replacement process, such as the cumulative error caused by the worm pair and the cycle error caused by the bevel gear, can achieve good results.

Also note that once the machine tool is adjusted, do not disassemble it at will, otherwise the accuracy will deteriorate immediately if the gear phase is disordered.

The author once modified an old gear hobbing machine in a factory. In two days, the cumulative error was reduced from 13.6′′ to 5.2′′. The factory immediately moved the machine tool to the constant temperature workshop as a master machine. It can be seen that this scheme is simple and easy to implement, and is very popular among users, and this technology is also easy to be promoted to the transformation of other gear processing machines.

Previous page

Hot Pipette Tips

The commonly used Pipette kits are mainly composed of a pipette and a pipette tip. The pipette tip is a single empty
Cavity reservoir; the pipette uses the principle of air displacement and controls the maximum displacement of the piston by rotating a screw with an ultra-fine thread
displacement, and then control the amount of liquid suction. There are the following problems when using the above kit for suction: 1. The suction volume is controlled by the pipette
After the pipette is sterilized or used for a period of time, it is easy to cause "hidden" failures, which cause the operator to be difficult to detect.
The actual suction volume is inaccurate, and it needs to be adjusted frequently, and the operation is cumbersome and time-consuming; 2. To improve the pipetting accuracy, the operator's
The operation requirements are high, and it is easily affected by factors such as the suction speed, the depth of the tip below the liquid level, and the inclination angle of the pipette.
The actual suction volume will be heard; 3. The actual suction volume will be affected because the suction head cover is not tight and leaking, and it will not be easily detected; 4.
When performing experiments that require high accuracy, such as analysis, in the operation of equal volume aspiration of liquids with different densities, the actual
The actual suction volume will be affected by the density itself; 5. In order to improve the accuracy, this type of pipette needs to carry out high
Cost-optimized design results in extremely high pipette costs.