How to manage dangerous chemicals


Before reading this article, please click on the blue font " China Chemical Safety Association " under the heading of this article and then click " Follow ", so you can receive the article for free. Share every day, completely free subscription, please rest assured!

main content

Standardized management of hazardous chemicals production enterprises

Eight systems: pollution prevention responsibility system, labeling system, management plan and filing system, declaration and registration system, source classification system, transfer order system, business license system, emergency plan and filing system

Three types of facilities: storage facilities, utilization facilities, disposal facilities

Business Training: Business Training Related to Hazardous Waste



Pollution prevention and control points

Implementation points:


Key point 1 : Establish a hazardous waste management system. Establish a responsibility system for the prevention and control of hazardous waste pollution, an internal management system, and measures to prevent and control the pollution of hazardous waste.

Point 2: Establish a chart of hazardous waste management. Dangerous waste management leading group and division of labor

Key point 3: Establish a job responsibility system. The duties and responsibilities of the main leaders, supervisors, competent departments, supervisors, supervisors of various production units, and production teams (employees) in the management of hazardous wastes.

Point 4: Establish safe operating procedures. The relevant regulations and requirements for the safe operation of hazardous waste processes in enterprises.

Standards for compliance: A responsibility system has been established. The responsible person is clear and the responsibilities are clear. The responsible person is familiar with the relevant regulations, systems, standards and norms for hazardous waste management.



Post the relevant content of the “pollution prevention responsibility system” to the main location of the plant


Pollution prevention and control points

Implementation points:

Key point 1: Hazardous waste containers and packaging must be labeled with hazardous waste.

Point 2: The facilities and places for collecting, storing, transporting, utilizing and disposing of hazardous waste must be provided with a hazardous waste identification mark.

Standards for compliance: According to the "Standards for the Control of Hazardous Waste Storage Pollution" (GB18597-2001) Appendix A and the "Environmental Protection Graphic Mark - Solid Waste Storage (Disposal) Field" (GB15562.2-1995 label set hazardous waste identification mark;



The identification mark is divided into warning signs and labels, and the contents of the labels are comprehensive.



1 All hazardous waste containers and packaging must be labeled with hazardous waste.

2 Collecting and storing hazardous waste facilities and places must also set warning signs and labels for hazardous waste.


Pollution prevention and control points

Implementation points:

Key point 1: The hazardous waste management plan includes measures to reduce the amount and harmfulness of hazardous waste generation.

Point 2: The hazardous waste management plan includes measures for the storage, utilization and disposal of hazardous waste.

Point 3: Report to the local environmental protection department at or above the county level for the record.

Key point 4: If there is a major change in the content of the management plan, it should be reported in time.

Standards for compliance: A hazardous waste management plan has been formulated: the content is complete, the production links, types, hazard characteristics, production quantities, and disposal methods of hazardous wastes are clearly described; reported to the environmental protection department for filing; and major changes are reported in a timely manner.

Units that need to develop a management plan:

The hazardous waste management plan shall be formulated by a unit that has independent legal personality or operates independently to produce hazardous waste. Subsidiaries and branches for units that have a subsidiary (having an independent unit legal person qualification), a branch or a branch (not having an independent unit legal person qualification), a group company or other economic complex producing hazardous waste Or the production bases of branch factories, group companies or other economic associations are separately formulated.

(Base of judgment: legal person qualification, independent operation, different counties)

Pollution prevention and control points

Implementation points:

Key point 1: Report the type, amount, flow, storage and disposal of hazardous waste to the local environmental protection department at or above the county level.

Point 2: If there is a major change in the declaration, it should be reported in time.

Standards for compliance: truthful declaration; complete content; can provide proof materials to prove the authenticity and rationality of the declared data.

Certification materials: EIA and acceptance approval, management plan and generating ledger

Declaration registration account

Hazardous waste accounts (or records) shall be established in the production workshop, storage place, and disposal site, in duplicate, one at the site and the other in time for archival filing.

Pollution prevention and control points

Key points for implementation: Collect and store according to the classification of hazardous waste characteristics.

Standards for compliance: The identification of hazardous waste packaging containers is clear; hazardous wastes are stored separately by type, and there are obvious intervals between different types of waste (such as aisles, etc.).

The implementation of the source classification system should:

1. Hazardous waste is separated from general waste;

2. Industrial waste is separated from office and domestic waste;

3. Solid, liquid, muddy, gaseous waste placed in the container is separated;

4. Separable from available waste;

5. The value of calorific value is separated from the waste without calorific value;

6. Separation of incompatible wastes;

7. Separation of utilization and disposal methods.

8, the big categories should be distinguished, each category should also be distinguished

The implementation of the source classification system should:

1. The identification of the hazardous waste packaging container is clear;

2. Hazardous wastes are stored separately by type;

3. There are obvious intervals between different types of waste (such as aisles and walls).

Pollution prevention and control points

Implementation points:

Point 1 : Before the transfer of hazardous waste, the hazardous waste transfer plan is approved and approved by the environmental protection department.

Point 2 : In the case of transferring hazardous wastes, in accordance with the relevant provisions of the “Administrative Measures on Transfer of Hazardous Wastes”, fill in the items produced in the transfer order and affix the official seal.

Point 3 : The transportation qualification meets the requirements: transport unit, transport vehicle, driver and escort. (The generating and transferring unit is responsible for reviewing the qualification of the transport unit)

Point 4 : The transfer order is fully saved.

Standards for compliance : There is a transfer plan approved by the environmental protection department. According to the actual transfer of hazardous waste, fill out the hazardous waste transfer joint order. The dangerous waste list before the inspection date is complete.

common problem:

Question 1 : The joint order should be applied to the local environmental protection bureau by the waste-producing enterprise after the transfer application is approved, and should not be issued by the operating enterprise;

Question 2 : The joint order should be one car, one class, one class, one single, not one car or one single class;

Question 3 : The total number of joint transfer orders should be consistent with the number of enterprise declarations and registrations, the number of transfer approvals, the number of transfer of account records, and the EIA data. If there is a large discrepancy, reasonable explanation should be made;

Question 4 : The second joint and deputy joint company of the joint order should be reported to the local environmental protection bureau for filing.

Question 5 : The transfer of hazardous waste between subsidiaries (subsidiaries) and branches of the group (company) should be implemented in the joint order system.

Hazardous waste generation unit transfer hazardous waste program

Transfer order operation program

Pollution prevention and control points

Implementation points:

Key point 1 : The transferred hazardous wastes are all provided or entrusted to the units holding hazardous waste business licenses for activities of collection, storage, utilization and disposal.

Point 2 : There is a contract for the use and disposal of hazardous waste signed with the hazardous waste business unit.

Standards for compliance : All units that are provided or entrusted to a hazardous waste business license in addition to storage and self-use disposal; there are contracts with units that hold hazardous waste business licenses.

Precautions:

Note 1 : Verify the scope of the license. The generating unit shall verify the qualifications and capabilities of the unit to be commissioned, and identify the types of hazardous wastes (including 8 hazardous waste codes and hazardous waste names) and quantities that are to be entrusted to the disposal unit.

Note 2 : Verify the license period. The signing of the entrusted disposal agreement shall be within the validity period of the business license of the business unit.

Note 3 : The agreement must be clear. In the agreement, the types, quantities and prices of hazardous wastes are clearly entrusted, and the forms of hazardous wastes (solid, semi-solid, liquid, etc.), packaging methods and modes of transportation are specified.

Note 4 : The internal subsidiaries and branches of the group (company) should also implement the licensing system as required.

Pollution prevention and control points

Implementation points:

Key point 1: Developed preventive measures and emergency plans for accidents.

Point 2: Record to the local environmental protection department at or above the county level.

Point 3: Organize emergency drills every year according to the requirements of the plan.

Standards for compliance: An emergency plan has been formulated and filed with the local environmental protection department. Emergency drills are organized in the current or previous year.

Precautions:

Note 1: Formulate the plan. In accordance with the requirements for the formulation of emergency plans, special emergency plans with measures to prevent accidents shall be formulated.

Note 2: Record according to law. To the local environmental protection department at or above the county level for the record, the county-level environmental protection department shall conduct a review and issue a certificate of possession. (The local environmental protection department may not refuse the filing of the enterprises in the jurisdiction)

Note 3: Organize the drill. There should be imagery of drill plans, drills, drills and drills for review. (Image data should be updated once a year)

Note 4: Full implementation. The production bases of subsidiaries (subsidiaries) or branch factories, group companies or other economic associations of the group (company) shall be separately formulated.



The drills should be drills for accidents involving hazardous wastes. Wear protective equipment, carry necessary emergency facilities and equipment, and do not mix fire drills with hazardous waste emergency drills.


Pollution prevention and control points

Implementation points:

Key point 1: Carry out environmental impact assessment according to law and complete the “three simultaneous” acceptance.

Point 2: Meet the relevant requirements of the "Hazardous Waste Storage Pollution Control Standards". nPoint 3: The storage period is not more than one year; if the storage period is extended, it shall be reported to the environmental protection department for approval.

Point 4: Hazardous waste that is not mixed and stored incompatible and not safely disposed of. Point 5: Hazardous waste is not mixed into non-hazardous waste for storage.

Point 6: Establish a hazardous waste storage ledger and record the storage of hazardous waste truthfully.

Standards for compliance:

1 Have EIA materials and complete the “three simultaneous” acceptance.

2 The ground of the storage site shall be hardened. The site shall have a canopy, cofferdam or Fence; the wastewater discharge pipe or channel shall be set up, and the washing wastewater shall be treated in the enterprise wastewater treatment facility; if liquid or semi-solid waste is stored, leakage shall also be provided. Liquid collection device; location 3 should be provided with a warning sign.

4 Containers loaded with hazardous waste are intact.

5 Hazardous waste should not be stored for more than one year; more than one year is approved by the environmental protection department.

6 to achieve classification and storage.

7 Have a ledger and record the storage of hazardous waste truthfully.

Storage room exterior

For ease of understanding, the storage facilities are divided into : storage rooms, storage, storage tanks, storage pools, storage yards.

Storage room: the company produces a relatively single species and a small amount of production waste

Warning signs, labels and related liability systems should be set up in the external walls of the storage room.

Storage room should have good ventilation or gas outlet

â—†In the storage room â—†

Establish hazardous waste storage and storage accounts, and make relevant records as required

Paste this type of waste identification mark in a prominent position in the area

Wastes of compatible nature but of different types can be stored in the same storage facility


In the storage room

The storage room floor (using the disposal workshop or place) must meet the requirements of the “Hazardous Waste Storage Pollution Control Standard” (GB18597-2001). If there is no EIA material support, the anti-seepage material should be re-laid on the original ground. If the storage is waste acid Alkali should also be treated with antiseptic treatment on the ground.

The ground should be significantly higher than the outdoor, the entrance should be set up with a fence, and the diversion canal and collection pool should be set around to strengthen the daily management to ensure that the ground should always be clean and see the true color.

Depot

Enterprises with a large number of hazardous wastes and a large number of enterprises should establish a storage warehouse, and the storage warehouse must be sealed. Other requirements are the same as storage




(Source: EHS Club)



[Editor: Chen Guofang]


Good things not only need to be collected, but also don't forget to share friends!


Meeting notice

The 2nd China International Chemical Process Safety Seminar and Chemical Safety Technology and Equipment Exhibition jointly organized by China Chemical Safety Association and the International Cooperation and Cooperation Center of the State Administration of Work Safety will be held from September 22 to 24, 2015. The day was held in Ningbo, Zhejiang Province.

Registration method : Please visit http://?oneid=20122 to download the registration form.




statement

The platform's neutrality of reprinting, sharing, presentation, and opinion is only to convey more information. It does not mean that the platform agrees with its views and is responsible for its authenticity. If you find any wrong information such as political, factual, technical errors and copyright issues, please contact us (Tel: 010-64464198 ), thank you for your support!